https://www.rockwellautomation.com/en-nl/products/details.100-D420EA11.html
Catalog #: 100-D420EA11
IEC 420 A MCS D Contactor
Catalog #: 100-D420EA11
IEC 420 A MCS D Contactor
Rockwell Automation announces that as of
2019-03-31T00:00:00.000Z,
the IEC 420 A MCS D Contactor will be discontinued and no longer available for sale.
Customers are encouraged to remove references to the affected product(s).
Discontinued Date:
2019-03-31T00:00:00.000Z
Replacement Category:
Engineering Replacement
Replacement Product:
100-E400ED11
[https://www.rockwellautomation.com/en-nl/products/details.100-E400ED11.html]
Learn how to avoid the risks of unauthorized and counterfeit products.
Technical Specifications
Electrical
Voltage type for actuating | AC/DC |
---|---|
Rated control supply voltage at AC 50 Hz | 208 V |
Rated control supply voltage at AC 60 Hz | 208 V |
Rated control supply voltage at DC | 200 V |
Type of electrical connection of main circuit | Screw connection |
Rated impulse withstand voltage (Uimp) | 12 kV |
Current (Ie), max | 420 A |
Optional overload relays | Electronic |
Current rating | 115 A |
Main current circuit resistance | 0.15 mOhm |
Rated filament current | 420 A @ 230/240V, AC-5b |
Rated isolation voltage (Ui) | 600V @ UL, CSA |
Auxiliary contacts | IP20 IEC 60529/DIN 40050 |
Rated power (enclosed) | 400 Hp @ 575V, 3-phase per UL/CSA |
Rated operational current for contactor | 248 A @ 230V, elevator duty (UL/CSA) |
Rated power for contactor | 75 Hp @ 200V, elevator duty (UL/CSA) |
General purpose current (enclosed) | 420 A per UL/CSA |
Power dissipation | 79.5 W @ 400V, AC-3, Ie |
Operating time | 35…110 ms @ DC, closing delay |
Short time withstand (Icw) | 4700 A for 10 s, 60 °C (140 °F) |
Coil consumption, hold-in | 7 W @ DC control |
Coil consumption, pick-up | 490VA/270 W @ 50 Hz, 60 Hz, 50/60 Hz |
Switching of 3-phase Capacitors | Single capacitor: 606 kVAR @ 1000V, AC-6b, 50 Hz, 40 °C |
Total power dissipation | DC control: 86.5 W @ 400V, AC-3, Ie |
Operating limits, dropout | (0.3...0.5) x Us @ DC control |
Switching of lamps | Gas discharge lamps, open: 450 A @ 40 °C (104 °F), AC-5a |
Insulation class of the coil | Class B per VDE 0660, table 22 |
Rating for switching AC motors | 425 kW @ 690V, 50 Hz, 3-phase (AC-2, AC-3) |
Operating limits, pick-up | (0.85...1.1) x Us @ DC control |
BS88 fuses current rating | Type 2 (per IEC 60947-4-1): 560 A @ 415V, 65 kA available fault current |
UL class L fuses rating | 1000 A @ 600V, 18 kA available fault current per UL 508 and CSA 22.2 No. 14 |
Rated voltage (Ue) | 690V @ AC, 50/60 Hz |
DIN fuses (gG, gL) current rating | Type 2 (per IEC 60947-4-1): 500 A @ 690V, 50 kA available fault current |
Coil voltage | 208-277V 50/60 Hz/230-250 50/60 Hz/200-255V DC electronic coil w/ electronic interface |
Rated operational current (Ie) | 727 A @ 690V, star-delta starting (50 Hz) |
UL class J and CSA HRCI-J fuses rating | Type2 (IEC60947-4-1): 600 A @ 100 kA available fault current per UL verified combination |
UL inverse-time circuit breaker | 600 A @ 600V, 30 kA available fault current per UL listed combination |
Switching of power transformers | Apparent power: 87.3 kVA @ 240V, AC-6a, 60 Hz (n = 30) |
Rated operational power (Pe) | 90 kW @ 400V, AC-4 (approximately 200000 operations) |
Switching of DC loads | 3-Poles in series: 425 A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C) |
Optional accessories | Side-mount auxiliary contacts, surge suppressors, IP20 terminal blocks, terminal shields, terminal covers, connecting components, terminal lugs, mechanical/electrical interlocks |
Features | Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil) |
Contacts | 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks |
Conventional coil type | Yes |
Electronic-EI coil type | Yes |
Rated coil frequency | AC 50 Hz, 50/60 Hz DC |
Mechanical
Frame terminal block conductor cross section, b max | 25 mm |
---|---|
Frame terminal block conductor cross section, s top | 6 mm |
Frame terminal block conductor cross section, s bottom | 6 mm |
Screw terminals | Thru-hole |
Conductor cross section, top opening | 25 mm² |
Conductor cross section, bottom opening | 25 mm² |
Vibration resistance | IEC 60068-2-6 |
Shock resistance | IEC 60068-2-27 |
Cross section per UL/CSA | 4 AWG...600 MCM @ top |
Lifespan | Mechanical DC control: 10000000 ops |
Switching frequency, max | 70 ops/h |
Recommended torque | 43 Nm |
Weight | Non-reverse: 7.5 kg @ DC |
Conductor cross section | Main contact, s maximum: 6 mm |
Protection class | IP00 IEC 60529/DIN 40050 |
Environmental
Altitude of installation site, max | 2000 m (NN), per IEC60947-1 |
---|---|
Protection against accidental contact | Finger-and back-of-hand proof per VDE 0106, part 100 |
Ambient temperature | Storage: -40…80 °C |
Construction
Single contactor cover | IP10 IEC 60529/DIN 40050 |
---|---|
Contactor with frame terminal block | IP20 IEC 60529/DIN 40050 |
Documentation
RESOURCE | PUBLICATION NUMBER |
---|---|
Installation Instructions | 100-IN042 |
Technical Data | 100-TD013 |
Find all available product literature for this product in the
Literature Library results.
Documentation
TYPE | Installation Instructions |
---|---|
PUBLICATION NUMBER | 100-IN042 |
TYPE | Technical Data |
PUBLICATION NUMBER | 100-TD013 |
Find all available product literature for this product in the
Literature Library results.
Copyright ©2024 Rockwell Automation, Inc.