Counters view parameters

The
Counters
view includes these parameters:
Parameter
Description
Counter
Indicates the counter number to which this configuration applies.
Rollover
Shows the rollover value.
When the counter counts up to this value, it is set to the Rollunder value when the next pulse is received.
Rollunder
Shows the rollunder value.
When the counter counts down to this value, it is set to the Rollover value when the next pulse is received.
Load Count Value
Shows the load count value.
Load Revolution Value
Shows the load revolution value.
Scalar
Specifies the scaling value for the counter.
  • Scale count, frequency, and acceleration values to Engineering Units in REAL by multiplying their integer values in pulses by the Scaling value.
  • For example: For motion applications, scale count, frequency, and acceleration to position, velocity, and acceleration/deceleration.