Points view parameters
Parameter | Description |
|---|---|
Point | Indicates the point to which the configuration applies. |
Fault Delay | Specifies the fault delay limit from 0 ms through 255 ms. The default is 80 ms. This parameter is not available in Run and Remote Run modes. |
Data Direction | Specifies the direction of the data. Valid values for each channel are:
This parameter is not available in Run and Remote Run modes. |
Enable Web Server | Enables the web server. This parameter is not available in Run and Remote Run modes. |
Enable Output Group Power Fault Reporting | Enables reporting of power faults. This parameter is not available in Run and Remote Run modes. |
Enable Output Group Fault | Enables output group fault when actuator power supply is unavailable. This parameter is not available in Run and Remote Run modes. |
Enable Digital Out Auto Restart | Enables the device to auto restart a digital output. This parameter is not available in Run and Remote Run modes. |
TIP:
If all the following conditions are met, selecting
Apply
or OK
automatically sends the information to the controller. The controller then tries to send the information to the device if the device's connection is not inhibited.- You are online in Program, Remote Program, or Remote Run mode.
- This controller is the owner controller.
- You have changed the device's configuration in the software.
Provide Feedback