Digital Inputs
The stepper module has two digital inputs that can be configured as a function trigger
for any of the axes.
Option | Description |
|---|---|
Simple Input | Use the input as a standard digital input. |
Home Limit Switch | Use the input to Indicate whether the home switch condition is
active. For more information, see Home Operation. |
Positive Overtravel Limit | Use the input to indicate whether the axis has reached the positive
overtravel limit. For more information, see Overtravel Detection. |
Negative Overtravel Limit | Use the input to indicate whether the axis has reached the negative
overtravel limit. For more information, see Overtravel Detection. |
Provide Feedback