Count/Internal Direction Mode

In this mode, the
O.Counterxx.Direction
tag determines the direction of the counter.
Count/Internal Direction Counting
Invert Counter Direction Setting
O.Counterxx.Direction
Tag
Input A (Count)
Input B (Not Used)
Change in Count Value
Disabled
0
Rising edge
1
1
Rising edge
-1
Enabled
0
Rising edge
-1
1
Rising edge
1
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.
Normal