SLC 500 enhanced: timer, counter, and control files: bit member addressing by bit address optional syntax

This addressing syntax applies to SLC 5/03 OS301 and SLC 5/04.
Fnnn:eee/bb
F
(file type)
T
Timer
C
Counter
R
Control
nnn
(optional file number)
Timer
4, 9-255 decimal
Counter
5, 9-255 decimal
Control
6, 9-255 decimal
Timer, counter and control file types use the default file number if the file number is absent. The default numbers are 4 (timer), 5 (counter) and 6 (control).
eee
(element number)
0-255 decimal
bb
(bit number)
Timer
13-15 decimal
Counter
10-15 decimal
Control
8-11, 13, 15 decimal
Example
T87:133/14
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.
Normal