Runtime Entitlement Sizing Guide

The tables in this section provide information on the features available with
FactoryTalk® Optix™
and the number of base or extended feature tokens that are required to use them. You can use any combination of features in an application, as long as the runtime base package meets the total number of required base feature tokens, and the runtime extended package meets the total number of required extended feature tokens.
IMPORTANT: Use the following tables for guidance only. See Runtime sizing tool for up-to-date token packages and how to determine the token package that best meets your needs.
Base Token Packages
Packages
Base package size
Base XS
Base S
Base M
Base L
Base XL
Base feature tokens included
5
8
11
15
21
You can add extended token packages to your base token package as your system requirements grow.
Extended Token Packages
Packages
Extended package size
XXS
XS
S
Extended feature tokens included
3
5
10
HMI Base Feature Tokens
Base Feature
Base Token Value
Core framework, graphics, data controls, charts, local user management
Included with all base token packages
HMI graphic rendering (1 client)
1
HTML5 HMI graphic rendering (1 web client)
1
HTML5 HMI graphic rendering (up to 3 web clients)
2
HTML5 HMI graphic rendering (up to 5 web clients)
3
HTML5 HMI graphic rendering (up to 10 web clients)
5
HTML5 HMI graphic rendering (up to 20 web clients)
7
Alarming (includes Alarm History)
1
Event Logger
1
Runtime retentivity
1
Data logger
1
Recipes
1
Basic PDF reporting
1
Audit signature
1
Active directory authentication
1
Document signature
1
OPC UA Base Feature Tokens
Base Feature
Base Token Value
OPC UA client:
FactoryTalk® Optix™
is a client to another OPC UA server
OPC UA Client – (connected to 1 server)
1
OPC UA Client – (connected to multiple servers)
2
OPC UA server:
FactoryTalk® Optix™
is a server to other OPC UA clients
OPC UA Server – (1 connected client)
1
OPC UA Server – (up to 3 connected clients)
2
OPC UA Server – (up to 5 connected clients)
3
OPC UA Server – (up to 10 connected clients)
5
OPC UA Server – (up to 20 connected clients)
7
Database Base Feature Tokens
Base Feature
Base Token Value
Database - Embedded InfluxDB
1
Database - Embedded SQLite
Included with Data logger
Database – External ODBC or InfluxDB (1 database connection)
1
Database – External ODBC or InfluxDB (up to 3 database connections)
2
Database – External ODBC or InfluxDB (up to 5 database connections)
3
MQTT Connectivity
Base Feature
Base Token Value
MQTT broker (max 25 connections)
1
MQTT subscriber
1 (per broker connection)
MQTT publisher
1 (per broker connection)
Controller Communications Features
Base Feature
Base Token Value
For
Logix 5000®
controllers
1 controller connection
0 or 1 depending on the runtime target device
Multiple controller connections
1 or 2 depending on the runtime target device
Runtime tag upload from controller
1
For non-
Allen-Bradley®
controllers
1 controller connection
1
Multiple controller connections
2
Runtime tag upload from controller (Siemens S7, Beckhoff)
1
Extended Token Features
Extended Feature
Extended Token Value
High availability (three-node cluster)
3
Workstation clients - 1 session
1
Workstation clients - up to 3 sessions
2
Workstation clients - up to 5 sessions
3
Workstation clients - up to 10 sessions
5
1 For
ASEM™
6300 industrial computers or devices with Optix embedded, one feature token is deducted for communication with
Rockwell Automation®
controllers.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.