Axis Statistical Attributes
    These are the attributes that provide useful statistics on motion axis operation.
Control Power-up Time
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | REAL  | -  | -  | -  | Seconds  | 
Elapsed time since the axis control power was last applied.
Cumulative Run Time
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | REAL  | -  | -  | -  | Hours  | 
Accumulated time that the axis has been powering the Running state.
Cumulative Energy Usage
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | REAL  | -  | -  | -  | Kilowatt Hours  | 
Accumulated output energy of the axis.
Cumulative Motor Rev
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - D  | Get/GSV  | LINT  | -  | -  | -  | 
Cumulative number of times the motor shaft has turned. (Rotary Motors Only).
Cumulative Main Power Cycles
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | DINT  | -  | -  | -  | 
Cumulative number of times AC Mains has been cycled.
Cumulative Control Power Cycles
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | DINT  | -  | -  | -  | 
Cumulative number of times Control Power has been cycled.
Cumulative Control Power-Up Time
Usage  | Access  | T  | Data Type  | Default  | Min  | Max  | Semantics of value  | 
|---|---|---|---|---|---|---|---|
Optional - XBD  | Get/GSV  | REAL  | -  | -  | -  | Hours  | 
Accumulated time that control power has been applied.
Provide Feedback