Low Flow Cut Off

Assign Process Variable Low Flow Cut Off

Select process variable for low flow cut off
Assign Process Variable Low Flow Cut Off parameter properties
Property
Value
Selection / Range
  • Off
  • Mass flow
  • Volume flow
  • Corrected volume flow
Factory Setting
Mass flow
*Depends on order options or device settings
Visibility
Operator
Write Access
Maintenance
Data Type
ENUM16

Off Value Low Flow Cutoff

Enter off value for low flow cut off
Off Value Low Flow Cutoff parameter properties
Property
Value
Selection / Range
0 - 100.0 %
Factory Setting
50 %
*Depends on order options or device settings
Visibility
Operator
Write Access
Maintenance
Data Type
FLOAT

On Value Low Flow Cutoff

Enter on value for low flow cut off
On Value Low Flow Cutoff parameter properties
Property
Value
Selection / Range
Depends on system units or other settings
Factory Setting
0
*Depends on order options or device settings
Visibility
Operator
Write Access
Maintenance
Data Type
FLOAT

Pressure Shock Suppression

Enter time frame for signal suppression (= active pressure shock suppression)
Pressure Shock Suppression parameter properties
Property
Value
Selection / Range
0 - 100 s
Factory Setting
0 s
*Depends on order options or device settings
Visibility
Operator
Write Access
Maintenance
Data Type
FLOAT