Diagnostics

Global - Device Name

(class 0x310, instance 1, attribute 27)
Type of the product.

Global - Status Signal

(class 0x310, instance 1, attribute 144)

Global - Device Tag

(class 0x310, instance 1, attribute 1)

Current - Module

Slot in which the Module is located. Sampler, Software and Analyzer are virtual modules.
Module slot encoding
Value
Slot
0
Slot 1
1
Slot 1
2
Slot 2
3
Slot 3
4
Slot 4
5
Slot 5
6
Slot 6
7
Slot 7
8
Sampler
9
Software
10
Analyzer

Current - Port

Number of connector on the extension module.

Current - Status Signal

Diagnostic category according Namur NE107 definition.
Status category encoding
Value
Status category
0
Ok
1
Failure
2
Function Check
4
Maintenance required
8
Out of Specification

Current - Diagnostic Code

See the product manual for a list of diagnostic codes and remedy information.

Current - Date

Date the diagnostic event was raised.

Current - Time

Time of day the diagnostic event was raised.

Last - Module

Slot in which the Module is located. Sampler, Software and Analyzer are virtual modules.
Module slot encoding
Value
Slot
0
Slot 1
1
Slot 1
2
Slot 2
3
Slot 3
4
Slot 4
5
Slot 5
6
Slot 6
7
Slot 7
8
Sampler
9
Software
10
Analyzer

Last - Port

Number of connector on the extension module.

Last - Status Signal

Diagnostic category according Namur NE107 definition.
Status category encoding
Value
Category
0
Ok
1
Failure
2
Function Check
4
Maintenance required
8
Out of Specification

Last - Diagnostic Code

See the product manual for a list of diagnostic codes and remedy information.

Last - Date

Date the diagnostic event was raised.

Last - Time

Time of day the diagnostic event was raised.