Remove and Install the IP54 Roof Vent Filters for Frame 7
Frame 7
Replace the IP54 roof vent filters on a power bay with kit catalog number SK-RM-PBFAN-54FLTR1. Follow these steps to remove and install the IP54 exhaust vent filters on a power bay.
- Review the product advisories in Before You Begin.
- Remove power from the system.
- Slide the vent up to release the tabs from the slots in the vent assembly and remove the vent.
- Remove the filter from the vent cover.
- IMPORTANT: Verify that the airflow direction arrow and “X” on the fiber filter media points inward, toward the interior of the enclosure.
- Install the IP54 exhaust vent filters on a power bay in the reverse order of removal.
Provide Feedback