Access to the Logix extended tag properties

FactoryTalk Linx Gateway supports access to Logix extended tag properties via the OPC UA, MQTT, and OPC DA interfaces.
TIP: Standalone data service does not support access to the Logix extended tag properties.
Prerequisites
  • Use the FactoryTalk Linx Gateway Professional activation.
  • Enable
    Extended Properties
    for tags in Studio 5000 Logix Designer.
  • Enable
    Upload all extended tag properties
    for the
    Processor
    ,
    Redundant Controller Path
    , or
    Redundant ControlLogix Controller
    shortcut in the
    Communication Setup
    editor.
These samples assume that you have a tag named "Tag1". To view the tag's extended properties in the client, use the following samples if the namespace mode is Folders with scalar data or Tag list and structures/array access:
  • [Shortcut]Tag1.@Description
  • [Shortcut]Tag1.@EngineeringUnit
  • [Shortcut]Tag1.@EngineeringLogging
  • [Shortcut]Tag1.@Max
  • [Shortcut]Tag1.@Min
  • [Shortcut]Tag1.@State0
  • [Shortcut]Tag1.@State1
    TIP: If you want to view the Logix extended tag properties in a program named "Program1", the sample is as follows:
    • [Shortcut]Program:Program1.Tag1.@Description
If the namespace mode is Custom namespace, map to a specific tag. For more information, see Extended tag properties.