Default ports used by FactoryTalk Action Manager
FactoryTalk Action Manager
uses the following two ports by default:- 5671forservice. If this port is allocated by another process, theFactoryTalk Action ManagerUIFactoryTalk Action Manageruser interface cannot be run.
- 5672forandFactoryTalk Action ManagerDatabase Serviceservice. If this port is allocated by another process, theFactoryTalk Action ManagerUIFactoryTalk Action Managerdatabase cannot be established.
If either port is allocated by a different software package, do one of the following:
- End the process which allocates the port and restart the service in WindowsServices.
- Change the port.
- Changeportandurlin C:\Program Files(x86)\Rockwell Software\FactoryTalk Action Manager\config\default.json. Restartservice after changing.FactoryTalk Action ManagerUI
- Changeportandurlin C:\Program Files(x86)\Rockwell Software\FactoryTalk Action Manager\mongod.cfg. Restartservice andFactoryTalk Action ManagerDatabase Serviceservice after changing.FactoryTalk Action ManagerUI