Status view

The
Status
view displays the current status of the axis and digital I/O signals.
TIP:
The available parameters depend on the
Axis Configuration
on the
General
view. Values are blank when the device is offline.
Motion Status
Parameter
Description
Actual position
Displays the current axis position in the configured position units.
The value is based on time-stamped feedback data received during cyclic updates.
Command position
Displays the commanded axis position generated by the motion planner in the configured position units.
Actual velocity
Displays the current axis speed and direction in the configured position units per second.
The value is calculated from changes in actual position over the update period.
Command velocity
Displays the commanded axis speed and direction, in the configured position units per second.
The value is based on the rate of change of the commanded position.
Axis Status
Parameter
Description
Axis Status
Displays axis state indicators. Each state includes a visual indicator that shows whether the condition is currently active.
States that are not applicable to the current axis configuration are shown as unavailable.
Axis Statuses include:
  • AC Line Power Loss
  • AC Line Phase Loss
  • AC Line Frequency Change
  • AC Line Sync Loss
  • AC Line Sync
  • AC Line Voltage Sag
  • Regenerating
  • Regenerative Power Limit
  • DC Bus Up
  • DC Bus Unload
  • Power Loss
  • Ride Thru
  • Shutdown
  • Reactive Power Limit
  • Motoring
  • Motoring Power Limit
  • Power Structure Enabled
  • Tracking Command
  • Feedback Integrity
  • Position Lock
  • Velocity Lock
  • Velocity Standstill
  • Bus Voltage Lock
  • Active Current Limit
  • Velocity Threshold
  • Velocity Limit
  • Torque Threshold
  • Torque Limit
  • Current Limit
  • Thermal Limit
  • Bus Voltage Limit
  • Reactive Current Limit
Digital I/O
Parameter
Description
Digital I/O
Displays the state of digital input and output signals. Each signal includes an indicator that shows whether the signal is currently active.
States that are not applicable to the current axis configuration are shown as unavailable.
Digital I/O include:
  • Enable
  • Home
  • Registration 1
  • Registration 2
  • Resistive Brake Output
  • Contactor Enable Out
  • Pre-Charge OK
  • Positive Overtravel
  • Negative Overtravel
  • Feedback Thermostat OK
  • AC Line Contactor OK
  • Regenerative Power OK In
  • Converter OK In
  • Bus Capacitor OK
  • Motor Thermostat OK
  • Mechanical Brake
  • Regenerative Power OK Out
  • Converter OK Out
  • Bus Conditioner Module OK
  • Shunt Thermal Switch OK