Autotune view
The
Autotune
view configures and performs automatic tuning of control loops to
improve axis performance.
TIP:
The
Autotune
view is available only when Axis Configuration
on the
General view is set to
Position Loop
or Velocity Loop
.Tune control loop by measuring load characteristics
Parameter | Description |
|---|---|
Application Type | Specifies the type of application to be tuned. Available options include:
Tip:
|
Loop Response | Specifies how tightly the control loop is tuned during
autotuning. Available options include:
Tip:
|
Load Coupling | Specifies how the load is mechanically coupled to the motor. Available options include:
This parameter is not available in online mode or when the axis is
enabled for motion. |
Customize gains to tune
TIP:
A blue arrow next to a control indicates that changes are committed immediately and
cannot be undone.
Parameter | Description |
|---|---|
Position Integrator Bandwidth | Specifies whether the position integrator bandwidth is included in
the autotune calculation. This checkbox is not available:
|
Velocity Integrator Bandwidth | Specifies whether the velocity integrator bandwidth is included in
the autotune calculation. This checkbox is not available:
|
Velocity Feedforward | Specifies whether velocity feedforward is included in the autotune
calculation. This checkbox is not available:
|
Acceleration Feedforward | Specifies whether acceleration feedforward is included in the
autotune calculation. This checkbox is not available:
|
Torque Low Pass Filter | Specifies whether the torque low pass filter is included in the
autotune calculation. This checkbox is not available:
|
Measure Inertia with Tune Profile | Specifies whether inertia is measured as part of the autotune
operation. When selected, the measured inertia values are displayed in the tuned
results when the test completes. This checkbox is not available:
|
Motor with Load | Measures inertia with the motor coupled to the load. This item is not available:
|
Uncoupled Motor | Measures motor inertia without the load coupled to the motor. This item is not available:
|
Travel Limit | Specifies the maximum travel distance used during the tune
operation. This parameter is not available:
|
Speed | Specifies the speed used during the tune operation. This parameter is not available:
|
Torque | Specifies the torque applied during the tune operation. The default
value is 100. This parameter is not available:
|
Direction | Specifies the direction of motion used during the tune operation. Available options include:
This parameter is not available:
|
Perform Tune
Parameter | Description |
|---|---|
Start | Starts the autotune operation. If there are pending edits, a dialog opens before the test starts.
Select Yes to apply the pending edits and continue. Select
No to cancel the test.Starting the operation issues a Motion Direct Command to the
controller. Parameters used by the command are validated before the
test begins. If the command cannot run because of an error, an error
message appears and Tune Status returns to Ready .This button is not available:
|
Stop | Stops an autotune operation that was started outside the current
Autotune view.Stopping the operation issues a Motion Direct Command to the
controller. This button is not available:
|
Tune Status | Displays the current status of the tuning operation. Available options include:
|
Loop Parameters Tuned | Displays the current parameter values and the values calculated
during the tuning operation. |
Advanced Compensation | Expands or collapses additional compensation settings used in tuning
calculations, including inertia, friction, and active torque
compensation. This section is not available in offline mode or when the axis is
Servo On. |
Load Parameters Tuned | Displays the current parameter values and the values calculated
during the tuning operation. |
Accept Tuned Values | Use Accept Tuned Values to commit the values from the Tuned
Value columns of the grid to the attribute, causing the Current
Value column to update.The blue arrow next to a control indicates that the data is
immediately committed. You do not have the opportunity to undo the
change. The Accept Tuned Values button is unavailable in offline mode
and if no test was successfully completed. |
Loop Parameters Tuned
TIP:
Parameters that do not apply to the current axis configuration are not displayed.
Parameter | Description |
|---|---|
Name | Displays the parameter name. |
Current | Displays the current value from the controller. |
Tuned | Displays the value calculated by the autotune operation. The column remains blank until a tune operation is started. If a
parameter is excluded from the tune calculation, its tuned value is
set to 0 . |
Units | Displays the units associated with the parameter. |
Advanced Compensation
TIP:
This section is not available in offline mode or in online mode when the axis is
Servo On.
Parameter | Description |
|---|---|
Inertia | Specifies the inertia value used in tuning calculations. If Use Load Ratio is selected on the Load view, this
value represents the load ratio. Otherwise, this value represents
the tune inertia or mass.This parameter is not available:
|
Compensate for Inertia | Specifies whether the inertia value is included in the tuning
calculation. If Measure Inertia with Tune Profile is selected, the
controller returns an inertia value after the tune operation. You
can use the returned value or enter a different value and run the
tuning calculation again.This checkbox is not available:
|
Friction | Specifies the friction value used in tuning calculations. This parameter is not available:
|
Compensate for Friction | Specifies whether the friction value is included in the tuning
calculation. If Measure Inertia with Tune Profile is selected, the
controller returns a friction value after the tune operation. You
can use the returned value or enter a different value and run the
tuning calculation again.This checkbox is not available:
|
Active Torque | Specifies the active torque value used in tuning calculations. This parameter is not available:
|
Compensate for Active Torque | Specifies whether the active torque value is included in the tuning
calculation. If Measure Inertia with Tune Profile is selected, the
controller returns an active torque value after the tune operation.
You can use the returned value or enter a different value and run
the tuning calculation again.This checkbox is not available:
|
Load Parameters Tuned
TIP:
Parameters that do not apply to the current axis configuration are not displayed.
Parameter | Description |
|---|---|
Name | Displays the parameter name. |
Current | Displays the current value from the controller. |
Tuned | Displays the value calculated by the autotune operation. The column remains blank until a tune operation is started. If a
parameter is excluded from the tune calculation, its tuned value is
set to 0 . |
Units | Displays the units associated with the parameter. |
Provide Feedback