Autotune view

The
Autotune
view configures and performs automatic tuning of control loops to improve axis performance.
TIP:
The
Autotune
view is available only when
Axis Configuration
on the General view is set to
Position Loop
or
Velocity Loop
.
Tune control loop by measuring load characteristics
Parameter
Description
Application Type
Specifies the type of application to be tuned.
Available options include:
  • Custom
    Allows manual adjustment of tuning parameters.
  • Basic
    (default)
    Uses general-purpose tuning settings.
  • Tracking
    Optimized for coordinated or following motion.
  • Point-to-Point
    Optimized for move-and-settle applications.
  • Constant Speed
    Optimized for steady-state velocity applications.
Tip:
  • This parameter is not available when the axis is enabled for motion.
  • Changing this parameter affects the following parameters: Velocity Integrator Hold, Position Integrator Hold, Gain Tuning Configuration Bits.
Loop Response
Specifies how tightly the control loop is tuned during autotuning.
Available options include:
  • Low
    More stable response with slower dynamics.
  • Medium
    (default)
    Balanced response and stability.
  • High
    Faster response with reduced damping.
Tip:
  • This parameter is not available in online mode or when the axis is enabled for motion.
  • Changing this parameter affects the Damping Factor parameter.
Load Coupling
Specifies how the load is mechanically coupled to the motor.
Available options include:
  • Rigid
    (default)
  • Compliant
This parameter is not available in online mode or when the axis is enabled for motion.
Customize gains to tune
TIP:
A blue arrow next to a control indicates that changes are committed immediately and cannot be undone.
Parameter
Description
Position Integrator Bandwidth
Specifies whether the position integrator bandwidth is included in the autotune calculation.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • When
    Application Type
    is not set to
    Custom
    .
Velocity Integrator Bandwidth
Specifies whether the velocity integrator bandwidth is included in the autotune calculation.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • When
    Application Type
    is not set to
    Custom
    .
Velocity Feedforward
Specifies whether velocity feedforward is included in the autotune calculation.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • When
    Application Type
    is not set to
    Custom
    .
Acceleration Feedforward
Specifies whether acceleration feedforward is included in the autotune calculation.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • When
    Application Type
    is not set to
    Custom
    .
Torque Low Pass Filter
Specifies whether the torque low pass filter is included in the autotune calculation.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • When
    Application Type
    is not set to
    Custom
    .
Measure Inertia with Tune Profile
Specifies whether inertia is measured as part of the autotune operation.
When selected, the measured inertia values are displayed in the tuned results when the test completes.
This checkbox is not available:
  • In online mode when the axis is Servo On.
  • In offline mode.
Motor with Load
Measures inertia with the motor coupled to the load.
This item is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Uncoupled Motor
Measures motor inertia without the load coupled to the motor.
This item is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Travel Limit
Specifies the maximum travel distance used during the tune operation.
This parameter is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Speed
Specifies the speed used during the tune operation.
This parameter is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Torque
Specifies the torque applied during the tune operation. The default value is 100.
This parameter is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Direction
Specifies the direction of motion used during the tune operation.
Available options include:
  • Forward Unidirectional
    (default)
  • Reverse Unidirectional
  • Forward Bi-Directional
  • Reverse Bi-Directional
This parameter is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When Inertia Tune is false.
Perform Tune
Parameter
Description
Start
Starts the autotune operation.
If there are pending edits, a dialog opens before the test starts. Select
Yes
to apply the pending edits and continue. Select
No
to cancel the test.
Starting the operation issues a Motion Direct Command to the controller. Parameters used by the command are validated before the test begins. If the command cannot run because of an error, an error message appears and
Tune Status
returns to
Ready
.
This button is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When a tune is in progress.
Stop
Stops an autotune operation that was started outside the current
Autotune
view.
Stopping the operation issues a Motion Direct Command to the controller.
This button is not available:
  • In offline mode.
  • In online mode when the axis is Servo On.
  • When the tune is ready to be executed.
  • When a tune started from
    Start
    in the current view.
Tune Status
Displays the current status of the tuning operation.
Available options include:
  • Ready
    (Default)
  • Success
  • Executing
  • Stopped by User
  • Time-Out Fault
  • Servo Fault
  • Exceeded Travel Limit
  • Axis Polarity Set Incorrectly
  • Measurement Fault
  • Configuration Fault
Loop Parameters Tuned
Displays the current parameter values and the values calculated during the tuning operation.
Advanced Compensation
Expands or collapses additional compensation settings used in tuning calculations, including inertia, friction, and active torque compensation.
This section is not available in offline mode or when the axis is Servo On.
Load Parameters Tuned
Displays the current parameter values and the values calculated during the tuning operation.
Accept Tuned Values
Use
Accept Tuned Values
to commit the values from the Tuned Value columns of the grid to the attribute, causing the Current Value column to update.
The blue arrow next to a control indicates that the data is immediately committed. You do not have the opportunity to undo the change.
The
Accept Tuned Values
button is unavailable in offline mode and if no test was successfully completed.
Loop Parameters Tuned
TIP:
Parameters that do not apply to the current axis configuration are not displayed.
Parameter
Description
Name
Displays the parameter name.
Current
Displays the current value from the controller.
Tuned
Displays the value calculated by the autotune operation.
The column remains blank until a tune operation is started. If a parameter is excluded from the tune calculation, its tuned value is set to
0
.
Units
Displays the units associated with the parameter.
Advanced Compensation
TIP:
This section is not available in offline mode or in online mode when the axis is Servo On.
Parameter
Description
Inertia
Specifies the inertia value used in tuning calculations.
If
Use Load Ratio
is selected on the
Load
view, this value represents the load ratio. Otherwise, this value represents the tune inertia or mass.
This parameter is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
Compensate for Inertia
Specifies whether the inertia value is included in the tuning calculation.
If
Measure Inertia with Tune Profile
is selected, the controller returns an inertia value after the tune operation. You can use the returned value or enter a different value and run the tuning calculation again.
This checkbox is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
  • When this checkbox is cleared.
Friction
Specifies the friction value used in tuning calculations.
This parameter is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
Compensate for Friction
Specifies whether the friction value is included in the tuning calculation.
If
Measure Inertia with Tune Profile
is selected, the controller returns a friction value after the tune operation. You can use the returned value or enter a different value and run the tuning calculation again.
This checkbox is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
  • When this checkbox is cleared.
Active Torque
Specifies the active torque value used in tuning calculations.
This parameter is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
Compensate for Active Torque
Specifies whether the active torque value is included in the tuning calculation.
If
Measure Inertia with Tune Profile
is selected, the controller returns an active torque value after the tune operation. You can use the returned value or enter a different value and run the tuning calculation again.
This checkbox is not available:
  • In offline mode.
  • When the axis is Servo On.
  • When
    Inertia Tune
    is not selected.
  • When the
    Tune Status
    is
    Success
    .
  • When this checkbox is cleared.
Load Parameters Tuned
TIP:
Parameters that do not apply to the current axis configuration are not displayed.
Parameter
Description
Name
Displays the parameter name.
Current
Displays the current value from the controller.
Tuned
Displays the value calculated by the autotune operation.
The column remains blank until a tune operation is started. If a parameter is excluded from the tune calculation, its tuned value is set to
0
.
Units
Displays the units associated with the parameter.
Provide Feedback
Have questions or feedback about this documentation? Please submit your feedback here.