Prescriptive Health Monitoring for Tank Process Variables

This solution enables the ROC to identify abnormal trends, process changes, and developing deviations before they impact tank performance. - [Implementation Time: 60 Minutes]
Innovation Center Home Page
Industrial water treatment facility with multiple filtration tanks and plumbing systems
Innovation Center LOGO
  • Overview
  • Implementation Guide
  • Download
  • Contact us
  • Subscribe
Innovation Center Home Page
 

Tank operations are one of the most important operations within the production process industries. In many processes, they represent the element responsible for maintaining the continuous movement of raw materials, semi-finished products, auxiliary services, and finished products. An unplanned failure can cause significant economic losses, safety risks, environmental impacts, and production of noncompliance.

Traditionally, these are monitored through levels, but we do not access the rate of change of their process variable. However, through the PlantPAx libraries, particularly by using the P_AI objects and the Cfg_HasRoC parameter of this library, it is possible to implement a Prescriptive Health Monitoring strategy capable of detecting early signs of operational degradation before a functional failure occurs.

The solution makes it possible to identify abnormal trends, changes in process dynamics, and progressive deviations that normally go unnoticed by traditional monitoring systems.

What does this application do?

In day-to-day operation, the value of a prescriptive solution is to provide the operator and maintenance personnel with enough time to act before the failure impacts the operation, thereby preventing the pump from potentially failing and avoiding the losses associated with not taking corrective actions.

  1. General Characteristics
  2. Advantages
Open All Close All
General Characteristics

A P_AI process library associated with a level variable is used as an example, and with it we can prescribe the drop in the equipment level as the pump develops an operational malfunction:

  • Prescriptive output variable Cfg_HasRoC
  • Input variable, pump stop failure due to an operational situation
Advantages
  • Early visibility of abnormal changes in critical equipment variables, associated with and extensible to measurement variables such as flow, pressure, level, and temperature.
  • Increase in operational stability, making it possible to identify gradual losses of capacity, common problems in pump suction and discharge, and possible effects extensible to cavitation and losses of hydraulic efficiency.
  • Better use of PlantPAx native capabilities, without the need for new additional hardware and licensing.
  • Early detection of operational equipment wear.
  • Solid operational knowledge prior to larger AI implementations.
AHIC Download ICON VF.png

Downloads

Please note: You will need to agree to the Terms & Conditions for each download.

Downloadable file ›
Legal Disclaimer Acceptance. ROCKWELL AUTOMATION WILL PROVIDE ACCESS TO ROCKWELL PRODUCTS (BEST PRACTICES, APPLICATIONS AND KNOWLEDGE) ON THE CONDITION THAT YOU ACCEPT AND COMPLY WITH THE FOLLOWING TERMS AND CONDITIONS. YOU ACCEPT AND AGREE TO BE BOUND BY THE TERMS OF THIS AGREEMENT BY DOWNLOADING, INSTALLING, COPYING, OR OTHERWISE USING PRODUCTS. IF YOU ARE ACCEPTING THESE TERMS ON BEHALF OF ANOTHER PERSON, COMPANY, OR OTHER LEGAL ENTITY, YOU REPRESENT AND WARRANT THAT YOU HAVE FULL AUTHORITY TO BIND THAT PERSON, COMPANY, OR LEGAL ENTITY TO THESE TERMS. IF YOU DO NOT AGREE TO THESE TERMS, DO NOT DOWNLOAD, INSTALL, COPY, ACCESS, OR USE THE PRODUCTS, SOFTWARE AND/OR CLOUD SERVICES. 1. Rockwell Automation retains full ownership and title to all Products and related documentation. No rights or licenses are granted other than those set forth in this Agreement. Company grants to Rockwell Automation a non-exclusive, worldwide, royalty-free, perpetual, non-revocable license to use any feedback Company provides regarding the Products, even if Company has designated the feedback as confidential. Rockwell Automation will be entitled to use the feedback without restriction or compensation to Company. 2. Company may not lease sub-lease, assign, license, sub-license or otherwise transfer any of the Products without the prior written consent of Rockwell Automation. Company may not assign or otherwise transfer access rights to the Products without the prior written consent of Rockwell Automation. Any reverse assembly, reverse engineering, decompilation, and creation of derivative works based on the Products by Company is prohibited. 3. Company acknowledges that Products provided under this Agreement are Rockwell Automation’s Confidential Information and are covered by effective or pending copyrights, patents, trademarks and/or trade secrets of Rockwell Automation, and Company agrees to maintain confidentiality by not disclosing Products or documentation to any third party without the prior written consent of Rockwell Automation and to protect the confidentiality of the Products as it would Company’s own confidential information. Company agrees that its obligation of confidentiality under this paragraph shall survive expiration or termination of this Agreement. 4. Company agrees that Products provided under this Agreement are prototypes and examples and its application and results may vary depending on each customer and project conditions. Rockwell Automation do not warranty the same results. This Agreement shall in no way be construed as a commitment by Rockwell Automation at any time to manufacture and/or offer Products for sale. There is no explicit or implicit service level agreement associated with using the Products. Rockwell Automation does not warrant that the functions contained in the Products will meet Company’s requirements. Company agrees to use all Products only in accordance with the instructions and only for the intended usages identified in the documentation. 5. EXCLUSION OF WARRANTIES AND LIMITATION OF LIABILITY. THE PRODUCTS ARE PROVIDED "AS IS". ROCKWELL AUTOMATION DISCLAIMS ANY AND ALL WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ROCKWELL AUTOMATION EXPLICITLY DISCLAIMS ALL WARRANTIES OF NON- INFRINGEMENT AND EXPRESSLY DOES NOT WARRANT THAT THE PRODUCTS, IN WHOLE OR IN PART, WILL BE ERROR FREE OR FREE FROM SECURITY VULNERABILITIES. IN NO EVENT SHALL ROCKWELL AUTOMATION BE LIABLE FOR (i) LOST PROFITS, LOST SAVINGS, DOWNTIME, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR (ii) ANY PERSONAL INJURY, PROPERTY DAMAGE OR ENVIRONMENTAL DAMAGE ARISING OUT OF OR IN CONNECTION WITH THIS AGREEMENT, WHETHER IN AN ACTION IN CONTRACT, STRICT LIABILITY OR IN TORT INCLUDING NEGLIGENCE. 6. COMPANY AGREES TO INDEMNIFY AND HOLD ROCKWELL AUTOMATION HARMLESS FROM ALL COSTS, AWARDS, DAMAGES, EXPENSES AND FEES (INCLUDING ATTORNEYS FEES) RESULTING FROM OR RELATED TO ANY THIRD-PARTY CLAIMS (INCLUDING EMPLOYEES AND AGENTS OF COMPANY) AGAINST ROCKWELL AUTOMATION, ITS DISTRIBUTORS, AGENTS, OFFICERS, DIRECTORS OR EMPLOYEES FOR PERSONAL INJURY (INCLUDING DEATH), PROPERTY DAMAGE OR ENVIRONMENTAL DAMAGE RELATED TO OR RESULTING FROM THE USE OF THE PRODUCTS. 7. In the event a Product is exported, Company agrees to comply with all applicable United States Export Control Law and Regulations, and the applicable export control laws of other countries. This Agreement shall be governed by the laws of the state of Wisconsin. This Agreement is the complete and exclusive Agreement between Rockwell Automation and the Company, and supersedes all prior agreements, whether written or oral, relating to the Products.
AHIC NEED HELP ICON VF.png


Need Help?

If you need help with an application or have feedback from the Innovation Center, please contact us.

 

Is this application relevant to me?

This application is useful for process engineers, automation and control engineers, maintenance engineers, and data scientists, so they can obtain prescriptive information from the equipment that uses it and thus generate actions that benefit the business.

 

How can I make it work?

Requirements: products, tools, prior knowledge.

Hardware

  • 1756-L85EP 

Software

  • Studio5000 (V37)

  • FactoryTalk Logix Echo Version 3.00.00

Prior Knowledge

  • FT Logix Echo
  • Products: Studio5000 (V37) | LogixEcho | PlantPax 5.5 | Process Libraries 5.2 | P_Ain
  • Tools: Studio 5000, FT LogixEcho, PlantPax 5.5, Process Libraries
 

Links of Interest (internal or external)

  • https://www.rockwellautomation.com/en-us/products/software/factorytalk/designsuite/studio-5000/studio-5000-logix-designer.html
  • https://www.rockwellautomation.com/en-us/products/software/factorytalk/designsuite/logix-echo.html
  • https://www.rockwellautomation.com/en-us/capabilities/process-solutions/process-systems/plantpax-distributed-control-system.html
  • https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=63590&v2=63590&o=&pdf=0
  • https://www.rockwellautomation.com/en-us/support/documentation/technical/capabilities/plantpax-process-solutions.html
 
 
 
 
AHIC STEP ICON.png

Implementation Guide

 
  1. Step 1
  2. Step 2
  3. Step 3
  4. Step 4
  5. Step 5
  6. Step 6
  7. Step 7
Open All Close All
Step 1
 

Select the file in Studio 5000

prescriptive-health-monitoring-for-tank-process-variables_Image, 1_Studio_5000_ACD.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 1_Studio_5000_ACD.png

Step 2
 

Open FT Logix Echo and connect it to Studio 5000. Configure FTLogixEcho so that it connects properly and operates correctly.

prescriptive-health-monitoring-for-tank-process-variables_002wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 2_FTLogixEcho_Connection.png

Step 3
 

Configuration of Prescriptive Routines, Initial Conditions and Final Condition.

prescriptive-health-monitoring-for-tank-process-variables_003wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 3_Studio5000_Configuration.png

Step 4
 

Configuration of Prescriptive Routines, maximum level, minimum level and derivative of volume Vs Time.

prescriptive-health-monitoring-for-tank-process-variables_004wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 4_Studio5000_Configuration_InitialCo.png

Step 5
 

Configuration of Prescriptive Routines, Health Monitoring and level simulation Page 1/2.

prescriptive-health-monitoring-for-tank-process-variables_005wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 5_Studio5000_Configuration_Pres.png

Step 6
 

Configuration of Prescriptive Routines, Range Change.

prescriptive-health-monitoring-for-tank-process-variables_006wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, _6_Studio5000_ROC.png

Step 7
 

ROC, real-time rate of change count.

prescriptive-health-monitoring-for-tank-process-variables_Image, 7_Studio5000_ROC.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 7_Studio5000_ROC.png

 
prescriptive-health-monitoring-for-tank-process-variables_Image, 1_Studio_5000_ACD.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 1_Studio_5000_ACD.png

prescriptive-health-monitoring-for-tank-process-variables_002wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 2_FTLogixEcho_Connection.png

prescriptive-health-monitoring-for-tank-process-variables_003wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 3_Studio5000_Configuration.png

prescriptive-health-monitoring-for-tank-process-variables_004wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 4_Studio5000_Configuration_InitialCo.png

prescriptive-health-monitoring-for-tank-process-variables_005wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 5_Studio5000_Configuration_Pres.png

prescriptive-health-monitoring-for-tank-process-variables_006wn.png

prescriptive-health-monitoring-for-tank-process-variables_Image, _6_Studio5000_ROC.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 7_Studio5000_ROC.png

prescriptive-health-monitoring-for-tank-process-variables_Image, 7_Studio5000_ROC.png

 
 

Prescriptive Health Monitoring for Tank Process Variables

Version 1.0 - September 2026

 
AHIC White Logo

Receive new applications and Innovation Center updates directly in your inbox.

Subscribe!
  1. Chevron LeftChevron Left Rockwell Automation Home
  2. Chevron LeftChevron Left Sup...
  3. Chevron LeftChevron Left Pro...
  4. Chevron LeftChevron Left Downloads
  5. Chevron LeftChevron Left Innovation Center
  6. Chevron LeftChevron Left Prescriptive Health Monitoring for Tank Process Variables
Please update your cookie preferences to continue.
This feature requires cookies to enhance your experience. Please update your preferences to allow for these cookies:
  • Social Media Cookies
  • Functional Cookies
  • Performance Cookies
  • Marketing Cookies
  • All Cookies
You can update your preferences at any time. For more information please see our {0} Privacy Policy
CloseClose