Loading
Allen-Bradley 1783-lms5 product image
Allen Bradley
Bestseller
1783-lms5

Stratix2500 5Port Lightly Managed Switch

PrintPrint
Drucken
EmailEmail
Freigeben
Product RegistrationProduct Registration
QR code
Allen-Bradley 1783-lms5 product image
Allen Bradley
Lebenszyklusstatus: Aktiv
Product at a glance
Product Registration
Lebenszyklusstatus: Aktiv
Product at a glance
Product Registration
Zur Stückliste hinzufügen
  • Produkt registrieren
  • Holen Sie sich Unterstützung
Technical Specifications
Drawings
Documents
Certifications
Accessories
Alternative Products
Technotes
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
38.1 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
5
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
4.2 W
Power dissipation
4.2 W
Power Input
12 - 24V DC, 0.3 - 0.2 A (SELV)
Total number of ports
5
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Zeichnungen
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Zeichnungen
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Typ Ressource Veröffentlichung
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Registration Link --
General Product Cutsheet --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um009_-en-p 1783-UM009
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
Suchen Sie nach weiterer Dokumentation?
Finden Sie kuratierte technische Dokumentation zu diesem Produkt im Technical Documentation Center oder durchsuchen Sie unsere vollständige Literaturbibliothek.
Besuchen Sie das Zentrum für technische Dokumentation Suche in der Literaturbibliothek
China CCC UKCA DOC UL Listed
  • Semiconductor Inds Immunit
  • China CCC
  • UKCA DOC
  • UL Listed Hazardous
  • UL Listed
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-11-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Elemente pro Seite:
1-1 von 1
Elemente pro Seite:
1-1 von 1
Suchen Sie nach weiteren Technotes?
In unserer Wissensdatenbank finden Sie Fragen und Antworten von technischen Experten von Rockwell Automation zu diesem Produkt.
Wissensdatenbank durchsuchen
Technische Spezifikationen
Network Media
Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
# of Copper Ports Required
8 or less
# of Fiber Ports Required
None
Stratix Ethernet Family
Stratix 2500
Width
38.1 cm
Height
144.8 cm
Depth
115 cm
Torque, functional ground lug screw
0.51 nm
Torque, power terminal screw
0.19 nm
Number of ports 10/100 Mbps RJ45
5
Layer 2
False
Layer 3
False
Manageable
True
Pulse (digital) output
4.2 W
Power dissipation
4.2 W
Power Input
12 - 24V DC, 0.3 - 0.2 A (SELV)
Total number of ports
5
Wire size, ethernet connection
RJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Ethernet
True
Wire size, DC power connection, solid or stranded copper wire rated at 30 °C, or greater, above the surrounding air temperature
0.82 mm²
Wire size, ground connection, solid or stranded copper wire
3.3 mm²
Wiring category on communication ports
2
Wiring category on power ports
2
Degree of protection (IP)
IP30
Housing base material
Open-style
Nominal position
T4
Delta connected motor power, max
T4
Temperature, surrounding air, maximum
60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports
±3
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports
±3
Emissions, CISPR11 (IEC 61000-6-4)
IEC 61000-6-4
ESD immunity, IEC 61000-4-2, air discharges
8 kV
ESD immunity, IEC 61000-4-2, contact discharges
6 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 2000 - 2700 MHz
3 kg/km
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 2000 MHz
10 kg/km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz
10 kg/km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)
30 g
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)
-20 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)
-20 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)
-20 °C
Ambient temperature, maximum
60 °C
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)
10 V
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 1890 MHz
10 kg/km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing
5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on communication ports
±2
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports
±2
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports
±1
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)
-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)
-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)
-40 °C
Zeichnungen
Zeichnungen
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Zeichnungen
2-Dimensional Drawing (PDF) Download (PDF)
3-Dimensional STEP model (STP) Download (ZIP)
Product Drawing Drawing (DWG)
Unterlagen
APPLICATION_TECHNIQUES_enet-at007_-en-p Application Techniques
ENET-AT007
APPLICATION_TECHNIQUES_enet-at006_-en-p Application Techniques
ENET-AT006
Product Registration Link General
--
Product Cutsheet General
--
1783-in016_-en-p Installation Instructions
1783-IN016
PROFILE_migrat-pp043_-en-p Profile
MIGRAT-PP043
REFERENCE_MANUAL_enet-rm002_-en-p Reference Manual
ENET-RM002
1783-um009_-en-p User Manual
1783-UM009
USER_MANUAL_1783-um007_-en-p User Manual
1783-UM007
Typ Ressource Veröffentlichung
Application Techniques APPLICATION_TECHNIQUES_enet-at007_-en-p ENET-AT007
Application Techniques APPLICATION_TECHNIQUES_enet-at006_-en-p ENET-AT006
General Product Registration Link --
General Product Cutsheet --
Installation Instructions 1783-in016_-en-p 1783-IN016
Profile PROFILE_migrat-pp043_-en-p MIGRAT-PP043
Reference Manual REFERENCE_MANUAL_enet-rm002_-en-p ENET-RM002
User Manual 1783-um009_-en-p 1783-UM009
User Manual USER_MANUAL_1783-um007_-en-p 1783-UM007
Suchen Sie nach weiterer Dokumentation?
Finden Sie kuratierte technische Dokumentation zu diesem Produkt im Technical Documentation Center oder durchsuchen Sie unsere vollständige Literaturbibliothek.
Besuchen Sie das Zentrum für technische Dokumentation Suche in der Literaturbibliothek
Zertifizierungen
China CCC UKCA DOC UL Listed
  • Semiconductor Inds Immunit
  • China CCC
  • UKCA DOC
  • UL Listed Hazardous
  • UL Listed
  • MOROCCO DOC
  • UK EX CERTIFICATE

This product was certified with the above certifications as of 2025-11-03. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Zubehör
Elemente pro Seite:
1-1 von 1
Alternative Produkte
Elemente pro Seite:
1-1 von 1
Technotes
Suchen Sie nach weiteren Technotes?
In unserer Wissensdatenbank finden Sie Fragen und Antworten von technischen Experten von Rockwell Automation zu diesem Produkt.
Wissensdatenbank durchsuchen
Loading
Finden Sie den nächstgelegenen Händler
Standort ändern
EmailEmail
PhonePhone
Finden Sie einen Partner
Stratix2500 5Port Lightly Managed Switch
CloseClose
1783-lms5
Schließen
Drucken
Allen-Bradley 1783-lms5 product image
Telefon:
Anruf
Rockwell Automation Home
Copyright ©2025 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation Startseite
  2. Chevron LeftChevron Left Produkte
Bitte aktualisieren Sie Ihre Cookie-Einstellungen, um fortzufahren.
Für diese Funktion sind Cookies erforderlich, um Ihr Erlebnis zu verbessern. Bitte aktualisieren Sie Ihre Einstellungen, um diese Cookies zuzulassen:
  • Social-Media-Cookies
  • Funktionale Cookies
  • Leistungscookies
  • Marketing-Cookies
  • Alle Cookies
Sie können Ihre Einstellungen jederzeit aktualisieren. Weitere Informationen finden Sie in unserem {0} Datenschutzrichtlinie
CloseClose