Loading
  • alt text
  • alt text
alt text
alt text
Bestseller
300-BOD930

NEMA Size 1 300 AC Contactor

PrintPrint
Drucken
EmailEmail
Freigeben
Product RegistrationProduct Registration
QR code
Allen-Bradley 300-BOD930 product image
Allen-Bradley 300-BOD930 product image
Allen-Bradley 300-BOD930 product image
Lebenszyklusstatus: Aktiv
Lebenszyklusstatus: Aktiv
Zur Stückliste hinzufügen
  • Holen Sie sich Unterstützung
Technische Spezifikationen
Allgemein
Mechanical
Electrical
Construction
Environmental
Zeichnungen
Unterlagen
Zertifizierungen
Zubehör
Alternative Produkte
Technotes
Mounting
Open Style
Number of auxiliary contacts as normally open contact
1
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Switching frequency, max
600 cycles/h, AC-1
Recommended torque
Main contacts: 2.5 Nm
Weight
AC/DC (Electronic): 0.48 kg (1.06 lbs.)
Conductor cross section
Main contacts, 2 conductor: 2.5...10 mm²
Protection class
Contactor main contacts: IP2X
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
120 V
Type of electrical connection of main circuit
Screw connection
Rated impulse voltage withstand (Uimp)
6 kV
NEMA size
Size 1
Conductor size
10 mm²
High energy efficient coil, pick-up
6 W @ 24V DC
High energy efficient coil, hold-in
1.7 W @ 24V DC
Main current circuit resistance
0.3 mΩ, 3-pole
Rated isolation voltage (Ui)
690V per IEC
Standard coil, pick-up
50VA/50 W @ 48...130V AC/DC
Standard coil, hold-in
2.2VA/2 W @ 48...130V AC/DC
Energy-efficient coil, hold-in
1.7VA/1.7 W @ 24-60V AC, 20-60V DC
Energy-efficient coil, pick-up
16VA/12...16 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed)
24A @ 600V per UL/CSA
Operating time, closing delay
40...95 ms (Standard coil)
Power dissipation
2.4 W per pole @ 400V, AC-1, Ie (4 pole)
Short time withstand (Icw)
3-Poles: 700A @ 1s, 40 °C
Operating time, opening delay
17...29 ms (High energy-efficient coil)
Rated operational current (enclosed)
25.3 A @ 200-208V, 3-phase per UL/CSA
Rated operational power (enclosed)
7.5 Hp @ 220-240V, 3-phase per UL/CSA
Electromagnetic compatibility
IEC 60947-1 - Environment A
Total power dissipation
4.7 W @ 400V, AC-3, Ie, AC/DC control (120-250V), 4 pole
Definite purpose rating
LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications
Operating limits, dropout
≤0.60 x Us @ DC control
Insulation class of the coil
Class F per IEC 60947-4-1
Operating limits, pick-up
(0.85...1.1) x Us @ 50/60 Hz
MCCB current rating
Type 2 (IEC 60947-4-1): 56A @ 400V, 70 kA available fault current
DIN fuses (gG) current rating
Type 2 (IEC 60947-4-1): 62A @ 400V, 100 kA available fault current
Rated voltage (Ue)
24, 48, 110, 220, 440V DC
Hp rating, max
7.5Hp @ 230V (60 Hz), 3-phase (Full-load current must not exceed continuous Aere)
Coil voltage
110V-50 Hz/120V-60 Hz
Switching of lighting loads
Tungsten lA, 3-phase (break all lines) (UL/CSA): 45A @ 600V
UL class RK5 fuses rating
Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 5 kA available fault current
Rated operational current (Ie)
9.6A @ 230V AC (1-phase), UL/CSA elevator duty (500000 electrical ops)
UL class J and CSA HRCI-J fuses rating
Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker
Type 1 combination (UL60947 and CSA 22.2 No.14): 100A @ 600V, 25 kA available fault current
Switching of power transformers
Apparent power: 9 kVA @ 200V, AC-6a @ 60Hz (n = 30)
Rated operational power (Pe)
6.5 kW @ 220-240V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
Switching of DC loads
4-Poles in series: 45A @ 220V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Number of power poles
Three pole + 1 NO auxiliary hold-in contact
Width
2.12 mm
Height
3.19 mm
Depth
4.06 mm
Enclosure
Open Type
Lug
No built-in lug
Climatic withstand
Category B according to IEC 60947-1, Annex Q
Ambient temperature
Storage: -60...80 °C (-76...176 °F)
Altitude, max
3000 m
Zeichnungen
3D STEP Model (STP) Herunterladen (ZIP)
Dimensions Drawing (PDF) Herunterladen (PDF)
Product Drawing Drawing (DXF)
Zeichnungen
3D STEP Model (STP) Herunterladen (ZIP)
Dimensions Drawing (PDF) Herunterladen (PDF)
Product Drawing Drawing (DXF)
Typ Ressource Veröffentlichung
Allgemein Specification Sheet --
Allgemein Circuit Protection Design and SCCR Tables --
Allgemein Product Cutsheet --
Technical Data 300-td003_-en-p 300-TD003
Suchen Sie nach weiterer Dokumentation?
Finden Sie kuratierte technische Dokumentation zu diesem Produkt im Technical Documentation Center oder durchsuchen Sie unsere vollständige Literaturbibliothek.
Suche in der Literaturbibliothek
  • Safety

This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Elemente pro Seite:
1-1 von 1
Elemente pro Seite:
1-1 von 1
Suchen Sie nach weiteren Technotes?
In unserer Wissensdatenbank finden Sie Fragen und Antworten von technischen Experten von Rockwell Automation zu diesem Produkt.
Wissensdatenbank durchsuchen
Technische Spezifikationen
Mounting
Open Style
Number of auxiliary contacts as normally open contact
1
Vibration resistance
IEC 60068-2-6
Shock resistance
IEC 60068-2-27
Switching frequency, max
600 cycles/h, AC-1
Recommended torque
Main contacts: 2.5 Nm
Weight
AC/DC (Electronic): 0.48 kg (1.06 lbs.)
Conductor cross section
Main contacts, 2 conductor: 2.5...10 mm²
Protection class
Contactor main contacts: IP2X
Voltage type for actuating
AC
Rated control supply voltage at AC 50 Hz
110 V
Rated control supply voltage at AC 60 Hz
120 V
Type of electrical connection of main circuit
Screw connection
Rated impulse voltage withstand (Uimp)
6 kV
NEMA size
Size 1
Conductor size
10 mm²
High energy efficient coil, pick-up
6 W @ 24V DC
High energy efficient coil, hold-in
1.7 W @ 24V DC
Main current circuit resistance
0.3 mΩ, 3-pole
Rated isolation voltage (Ui)
690V per IEC
Standard coil, pick-up
50VA/50 W @ 48...130V AC/DC
Standard coil, hold-in
2.2VA/2 W @ 48...130V AC/DC
Energy-efficient coil, hold-in
1.7VA/1.7 W @ 24-60V AC, 20-60V DC
Energy-efficient coil, pick-up
16VA/12...16 W @ 24-60V AC, 20-60V DC
General purpose current (enclosed)
24A @ 600V per UL/CSA
Operating time, closing delay
40...95 ms (Standard coil)
Power dissipation
2.4 W per pole @ 400V, AC-1, Ie (4 pole)
Short time withstand (Icw)
3-Poles: 700A @ 1s, 40 °C
Operating time, opening delay
17...29 ms (High energy-efficient coil)
Rated operational current (enclosed)
25.3 A @ 200-208V, 3-phase per UL/CSA
Rated operational power (enclosed)
7.5 Hp @ 220-240V, 3-phase per UL/CSA
Electromagnetic compatibility
IEC 60947-1 - Environment A
Total power dissipation
4.7 W @ 400V, AC-3, Ie, AC/DC control (120-250V), 4 pole
Definite purpose rating
LRA: 270 A @ 440-480V AC (3-phase), UL/CSA HVAC applications
Operating limits, dropout
≤0.60 x Us @ DC control
Insulation class of the coil
Class F per IEC 60947-4-1
Operating limits, pick-up
(0.85...1.1) x Us @ 50/60 Hz
MCCB current rating
Type 2 (IEC 60947-4-1): 56A @ 400V, 70 kA available fault current
DIN fuses (gG) current rating
Type 2 (IEC 60947-4-1): 62A @ 400V, 100 kA available fault current
Rated voltage (Ue)
24, 48, 110, 220, 440V DC
Hp rating, max
7.5Hp @ 230V (60 Hz), 3-phase (Full-load current must not exceed continuous Aere)
Coil voltage
110V-50 Hz/120V-60 Hz
Switching of lighting loads
Tungsten lA, 3-phase (break all lines) (UL/CSA): 45A @ 600V
UL class RK5 fuses rating
Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 5 kA available fault current
Rated operational current (Ie)
9.6A @ 230V AC (1-phase), UL/CSA elevator duty (500000 electrical ops)
UL class J and CSA HRCI-J fuses rating
Type 1 combination (UL60947 and CSA 22.2 No.14): 60A @ 600V, 100 kA available fault current
UL inverse-time circuit breaker
Type 1 combination (UL60947 and CSA 22.2 No.14): 100A @ 600V, 25 kA available fault current
Switching of power transformers
Apparent power: 9 kVA @ 200V, AC-6a @ 60Hz (n = 30)
Rated operational power (Pe)
6.5 kW @ 220-240V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
Switching of DC loads
4-Poles in series: 45A @ 220V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)
Number of power poles
Three pole + 1 NO auxiliary hold-in contact
Width
2.12 mm
Height
3.19 mm
Depth
4.06 mm
Enclosure
Open Type
Lug
No built-in lug
Climatic withstand
Category B according to IEC 60947-1, Annex Q
Ambient temperature
Storage: -60...80 °C (-76...176 °F)
Altitude, max
3000 m
Zeichnungen
Zeichnungen
3D STEP Model (STP) Herunterladen (ZIP)
Dimensions Drawing (PDF) Herunterladen (PDF)
Product Drawing Drawing (DXF)
Zeichnungen
3D STEP Model (STP) Herunterladen (ZIP)
Dimensions Drawing (PDF) Herunterladen (PDF)
Product Drawing Drawing (DXF)
Unterlagen
Specification Sheet Allgemein
--
Circuit Protection Design and SCCR Tables Allgemein
--
Product Cutsheet Allgemein
--
300-td003_-en-p Technical Data
300-TD003
Typ Ressource Veröffentlichung
Allgemein Specification Sheet --
Allgemein Circuit Protection Design and SCCR Tables --
Allgemein Product Cutsheet --
Technical Data 300-td003_-en-p 300-TD003
Suchen Sie nach weiterer Dokumentation?
Finden Sie kuratierte technische Dokumentation zu diesem Produkt im Technical Documentation Center oder durchsuchen Sie unsere vollständige Literaturbibliothek.
Suche in der Literaturbibliothek
Zertifizierungen
  • Safety

This product was certified with the above certifications as of 2025-12-23. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.

Zubehör
Elemente pro Seite:
1-1 von 1
Alternative Produkte
Elemente pro Seite:
1-1 von 1
Technotes
Suchen Sie nach weiteren Technotes?
In unserer Wissensdatenbank finden Sie Fragen und Antworten von technischen Experten von Rockwell Automation zu diesem Produkt.
Wissensdatenbank durchsuchen
Loading
Finden Sie den nächstgelegenen Händler
Contact your distributor in {0}
Standort ändern
EmailEmail
PhonePhone
Finden Sie einen Partner
NEMA Size 1 300 AC Contactor
CloseClose
300-BOD930
Schließen
Drucken
Chevron LeftChevron Left
Allen-Bradley 300-BOD930 product image
Chevron LeftChevron Left
Allen-Bradley 300-BOD930 product image
Allen-Bradley 300-BOD930 product image
Telefon:
Anruf
Rockwell Automation Home
Copyright ©2026 Rockwell Automation, Inc.
  1. Chevron LeftChevron Left Rockwell Automation Startseite
  2. Chevron LeftChevron Left Produkte
Bitte aktualisieren Sie Ihre Cookie-Einstellungen, um fortzufahren.
Für diese Funktion sind Cookies erforderlich, um Ihr Erlebnis zu verbessern. Bitte aktualisieren Sie Ihre Einstellungen, um diese Cookies zuzulassen:
  • Social-Media-Cookies
  • Funktionale Cookies
  • Leistungscookies
  • Marketing-Cookies
  • Alle Cookies
Sie können Ihre Einstellungen jederzeit aktualisieren. Weitere Informationen finden Sie in unserem {0} Datenschutzrichtlinie
CloseClose